Schneider GV2LE14 | Motor circuit breaker, TeSys GV2, 3P, 10 A, magnetic, toggle control, screw clamp terminals
Description
Schneider GV2LE14 | Motor circuit breaker, TeSys GV2, 3P, 10 A, magnetic, toggle control, screw clamp terminals

Description
The Schneider GV2LE14 is a TeSys Deca frame 2 motor circuit breaker designed for short-circuit protection in three-phase motor control applications. Rated at 10A, it features three poles, magnetic trip technology, toggle control, and screw clamp terminals for reliable integration into industrial motor starter systems.
The Schneider GV2LE14 uses magnetic-only protection, providing fast protection against short-circuit currents. For complete motor protection against overload conditions, the breaker should be combined with a compatible external thermal overload relay.
With a magnetic tripping current of approximately 138A, the Schneider GV2LE14 provides rapid circuit interruption during severe overcurrent conditions while allowing normal motor starting currents to pass without unnecessary tripping.
The breaker provides a high rated ultimate short-circuit breaking capacity of up to 100kA at 400/415V AC, making it suitable for demanding industrial electrical systems. It supports operating voltages up to 690V AC at 50/60Hz.
For motor applications, the Schneider GV2LE14 can be used with three-phase motors rated up to approximately 4kW at 400/415V AC, depending on the complete starter configuration and motor characteristics.
Its compact 45mm width and standard 35mm DIN-rail mounting make the Schneider GV2LE14 easy to integrate into motor control centers, automation panels, machine control cabinets, and industrial switchboards.
With high short-circuit breaking performance, magnetic protection, durable mechanical construction, and compatibility with the Schneider TeSys motor control ecosystem, the Schneider GV2LE14 provides a practical solution for professional motor starter and protection applications.
Additional information
| brands | Schneider Electric |
|---|
Brand
Schneider Electric
data sheet
specifications
| Range | TeSys Deca |
|---|---|
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2LE |
| Device application | Motor protection |
| Trip unit technology | Magnetic |
| Poles description | 3P |
|---|---|
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 3 kW at 400/415 V AC 50/60 Hz 4 kW at 400/415 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz 5.5 kW at 690 V AC 50/60 Hz 7.5 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Toggle |
| [In] rated current | 10 A |
| Magnetic tripping current | 149 A |
| [Ith] conventional free air thermal current | 10 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 1.8 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections – terminals | Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² – solid Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² – flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² – flexible with cable end |
| Tightening torque | 1.7 N.m – on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |
| Net weight | 0.33 kg |
| Colour | Dark grey |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ |
|---|---|
| Product certifications | CB Scheme CE UKCA CCC cULus EAC LROS (Lloyds register of shipping) BV RINA DNV-GL |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5…150 Hz |
| Operating altitude | <= 2000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.500 cm |
| Package 1 Width | 9.300 cm |
| Package 1 Length | 4.800 cm |
| Package 1 Weight | 270.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.830 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 119.460 kg |
| Warranty (in months) | 18 |
|---|